Chapter 12

NCERT
Class 10
Science
Solutions
2. An electric oven with 2 kW power rating is operated in a domestic electric circuit (220 V) that has a current rating of 5 A. What result do you expect? Explain.
Promo GIF

Question:

An electric oven with 2 kW power rating is operated in a domestic electric circuit (220 V) that has a current rating of 5 A. What result do you expect? Explain.

Answer:

Here I = ?, R = ?, P = 2kW = 2 × 103 W, V = 220 V

Using formula, P = V2 / R

⇒ R = V2 / P

R = (220 X 220) / (2 X 103)

R = (484 X 102) / (2 X 103)

R = 242 X 10-1

Using formula V = IR

I = V/R

I = 220 x 10/ 242

I = 2200 / 242

I= 9.09A

The current (9.09 A) exceeds the fuse rating (5 A) of the given circuit. Due to this, the fuse is broken due to the high flow of current through the circuit.

Buy Latest Books

Teacher's Corner